Technical overview HP ProCurve Switch 5400zl, 3500yl, and 6200yl Series Table of contents Executive summary ...
10 HP ProCurve Switch 5400zl Series The HP ProCurve Switch 5400zl series is a high-end edge switch. This switch series has been designed to be a f
11 Figure 2. HP ProCurve Switch 5400zl Chassis and Bundles The HP ProCurve Switch 5406zl-48G Intelligent Edge (J8699A) and 5412zl-96G Intellige
12 However, when the management module is removed, all ports lose communication and the system will be powered down. Figure 3. HP ProCurve Swit
13 The internal power supplies are inserted in the back slots. These slots are labeled PS1 and PS2 on the 5406zl and PS1 through PS4 on the 5412zl
14 Both internal supplies have over-current, over-temperature, and over-voltage protection, as well as integrated fans. Hot swapping is allowed, t
15 In the event of an individual fan failure, an SNMP trap and event log entry are generated. Figure 6. Fan tray for switch 5406zl (J8697-6000
16 Each of the copper-based line interface modules provides integrated PoE capability. 24-port 10/100/1000 20-port 10/100/1000 + 4-port Mini
17 Switch model Minimum internal Maximum internal Internal + external 5406zl 1 2 4 5412zl 2 4 6 Table 1. Minimum and maximum power supply sup
18 Note that two 875W internal power supplies cannot supply sufficient PoE power to a 5406zl switch fully populated with 24-port line interface mo
19 Figure 9. HP ProCurve Switch 5406zl management module block diagram Processor The CPU processor is a Freescale PowerPC 8540 operating at 66
2 Specifications ... 18 Management module ...
20 HP ProCurve Switch 5400zl 24p 10/100/1000 PoE Module (J8702A) Description This line interface module has 24 10/100/1000Base-T ports that p
21 • J4860C HP ProCurve Gigabit-LH-LC Mini-GBIC • J8177C HP ProCurve Gigabit 1000Base-T Mini-GBIC • J9142B HP ProCurve 1000-BX-D SFP-LC Mini-GB
22 Transceivers supported (ordered separately) • J8436A HP ProCurve 10-GbE X2-SC SR Optic • J8437A HP ProCurve 10-GbE X2-SC LR Optic • J8438A H
23 services, enabling a resilient, highly secure, mobile multi-service network. Each “WES” Module can control up to 156 HP ProCurve Radio Ports (l
24 HP ProCurve Switch 3500yl Series The HP ProCurve Switch 3500yl series is another of the most advanced intelligent edge switches in the HP ProCu
25 The table below shows examples of the maximum number of PoE ports that can be supported by the two 3500yl switch models. One column shows the m
26 Specifications Processor The CPU processor is a Freescale PowerPC 8540 operating at 667 MHz. Memory SDRAM Synchronous Dynamic RAM is used for
27 HP ProCurve Switch yl 10-GbE 2p CX4 + 2p X2 Module (J8694A) Description This 10-GbE line interface module has two fixed CX4 ports and two X
28 HP ProCurve Switch 6200yl-24G-mGBIC (J8992A) Figure 11. HP ProCurve Switch 6200yl Processor The CPU processor is a Freescale PowerPC 8540
29 Overview of features and benefits The HP ProCurve Switch 5400zl, 3500yl, and 6200yl series use the same software image base. For the HP ProCurv
3 Appendix C: Power over Ethernet ... 47 PoE device types ...
30 • Identity-driven ACL: enables implementation of a highly granular and flexible access security policy specific to each authenticated network
31 Layer 2 switching • HP ProCurve switch meshing: dynamically load-balances across multiple active redundant links to increase available aggrega
32 • Server-to-Switch Distributed Trunking: enables load-balancing and increases resiliency between a server and multiple switches. This feature
33 Standards and protocols Device management RFC 1591 DNS (client) HTML and telnet management General protocols IEEE 802.1ad Q-in-Q (Premium Lice
34 IPv6 RFC 1981 IPv6 Path MTU Discovery RFC 2460 IPv6 Specification RFC 2461 IPv6 Neighbor Discovery RFC 2462 IPv6 Stateless Address Auto-configu
35 QoS/Cos RFC 2474 DiffServ Precedence, including 8 queues/port RFC 2597 DiffServ Assured Forwarding (AF) RFC 2598 DiffServ Expedited Forwarding
36 Per-port buffer sizes The HP ProCurve Switch 5400zl, 3500yl, and 6200yl series have eight hardware queues to which prioritized traffic can be a
37 Optimizing the 10-GbE port configuration The 10-GbE modules (J8707A, J8708A, and J8694A) used in the HP ProCurve Switch 3500yl, 5400zl, and 620
38 Figure 13. Approach for guaranteeing 10 Gbps on a specific port Connection choices are also important where equally balanced bandwidth is n
39 Throughput and latency performance data The following three tables describe the performance capabilities of the 10 Gbps, 1 Gbps, and 100 Mbps l
4 Executive summary HP ProCurve Networking has an extensive line of networking products built around the concept of the HP ProCurve Adaptive EDGE
40 10 Gbps Throughput % Packets per second Full mesh % drops Latency (FIFO) Latency (LIFO) Packet size L2/L3 L2/L3 L2 (µsecs) L3 (µsecs) L2 (µ
41 10 Gigabit performance traffic patterns In the prior table, the performance levels for 10 Gigabit ports assume the underlying traffic patterns
42 HP ProCurve warranty and support Industry-leading warranty HP ProCurve Networking products come with warranties you would expect from HP. • H
43 Appendix A: Premium License This section of the Technical Overview provides additional background information about the HP ProCurve Switch 5400
44 Two methods for managing Premium Edge licensing on ProCurve Switch 5400zl and 3500yl series• Manually using ProCurve web portal and CLI co
45 On a subsequent window, you select premium-edge for the Feature Group and type the registration ID you received with the purchase of the Pr
46 Policy Enforcement Engine benefits The Policy Enforcement Engine has several benefits: • Granular policy enforcement The initial software rele
47 Appendix C: Power over Ethernet The IEEE 802.3af standard for Power over Ethernet (PoE) enables Ethernet switches to provide power, as well as
48 Power delivery options The 802.3af standard provides two options for providing power over CAT 5 Ethernet cable. They are: • Unused pairs—This
49 Support for pre-802.3af standard powered devices The HP ProCurve Switch 5400zl and 3500yl series also support a number of pre-802.3af standard
5 Product positioning Overview A widely used method for segmenting the areas in which switches are installed calls for three different classificat
50 In order to receive a multicast stream, routers explicitly join the stream by sending join messages to the RP. This join message is analogous t
51 LLDP-MED endpoint devices are located at the network edge and communicate using the LLDP-MED framework. Any LLDP-MED endpoint device belon
52 Virus Throttle works by intercepting IP connection requests, that is, connections in which the source subnet and destination address are differ
53 Response options The response behavior of connection-rate filtering can be adjusted by using filtering options. When a worm-like behavior is de
54 The VRRP Master router periodically sends advertisements to a reserved multicast group address. The VRRP Backup routers listen for advertisemen
55 Appendix H: OSPF Equal Cost Multipath In Open Shortest Path First (OSPF), if different subnet destinations in a network are reachable through m
56 Appendix I: Advanced Classifier-Based QoS Released with software version K.14, the Advanced Classifier-Based QoS provides: • A finer granulari
57 Appendix J: Server-to-Switch Distributed Trunking Distributed Trunking is a link aggregation technique where two or more links across two switc
58 • ISC port can be an individual port or a manual LACP trunk, but a dynamic LACP trunk can’t be configured as an ISC port. • Maximum of 8 link
59 LED State Indication Blinking (orange) If DIMM, Fault, and Self Test LEDs are blinking, DIMM failed self-test. If DIMM and Fault LEDs are bli
6 • Diagnostic—remote intelligent mirroring, loopback interface, UDLD, sFlow support • Investment protection—upgradable management engine and CP
60 Modules A, B, C, D, E, F, G, H, I, J, K, L On (green) A module is installed in the switch module slot corresponding to the letter and the mo
61 The LED status indicators for the HP ProCurve Switch 5400zl series switch modules are described in the following table. LED State Indication
62 LED State Indication Temp On (green) Internal temperature is normal. Blinking (orange) An over temperature condition has been detected. Fa
63 LED State Indication PoE (green) Indicates which ports are supplying power: • If the Mode LED is on, the port is providing PoE power. • If t
64 The switches normally ship with a rack-mounting kit that allows installation into a two-post, 19-inch data communications rack. If installation
The table below lists the part numbers of power cords that can be used with the HP ProCurve Switch 5400zl, 3500yl, and 6200yl series products. The
7 Figure 1. ProVision ASIC Architecture for HP ProCurve Switch 5406zl The diagram above illustrates an example of the logical interconnection
8 Policy Enforcement Engine The ProVision ASICs on each line interface module contain the Policy Enforcement Engine. This engine provides fast pac
9 ProVision ASIC CPU Each ProVision ASIC contain its own CPU for learning of Layer 2 nodes, packet sampling for the XRMON function, handling local