ProCurve 420 Informations techniques Page 296

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 363
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 295
Command Line Reference
Ethernet Interface Commands
shutdown
This command disables the Ethernet interface. To restart a disabled interface,
use the no form.
Syntax
shutdown
no shutdown
Default Setting
Interface enabled
Command Mode
Interface Configuration (Ethernet)
Command Usage
This command allows you to disable the Ethernet interface due to
abnormal behavior (e.g., excessive collisions), and re-enable it after the
problem has been resolved. You may also want to disable the Ethernet
interface for security reasons.
Example
The following example disables the Ethernet interface.
HP420(if-ethernet)#shutdown
HP420(if-ethernet)#
speed-duplex
This command configures the speed and duplex mode of the Ethernet inter-
face when auto-negotiation is disabled. Use the no form to restore the default.
Syntax
speed-duplex <auto | 10MH | 10MF | 100MH | 100MF>
auto - autonegotiate the speed and duplex mode
10MH - Forces 10 Mbps, half-duplex operation
10MF - Forces 10 Mbps, full-duplex operation
100MH - Forces 100 Mbps, half-duplex operation
100MF - Forces 100 Mbps, full-duplex operation
8-90
Vue de la page 295
1 2 ... 291 292 293 294 295 296 297 298 299 300 301 ... 362 363

Commentaires sur ces manuels

Pas de commentaire